EARD6
(în stoc)
AIR VENT: EARD6 VENTILATION DAMPER. DAMPER IS NORMALLY CLOSED, POWER OPEN, SPRING RETURN. USED WITH W8150 FOR FRESH AIR VENTILATION.
32004629-001
(în stoc)
BONNET ADAPTER KIT: 32004629-001 BONNET ADAPTER KIT TO ADAPT (LANDIS/ POWERS) FLOWRITE 599 1/2-3 IN GLOBE VALVE,USE W/Q5020A OR B-REQUIRED SEE PROD DATA 63-2552
RM7896D1027
(în stoc)
BURNER CONTROL: RM7896D1027 BURNER CONTROL 120V, 50/60 HZ. SWITCH CHECK. 15 SEC POSTPURGE. PURGE LED INSTEAD OF STANDARD FLAME LED. POWER LED BLINKS ALARM CODE ON LOCKOUT.
R8239A1052
(în stoc)
CONTACT: R8239A1052 TRADELINE FAN CENTER 120V PRIMARY, 24V SECON- DARY W/PLUG-IN SPDT RELAY 1 N.0. AND 1 N.C. POWER CONTACTS
R8239B1043
(în stoc)
CONTACT: R8239B1043 SUPER TRADELINE. DPDT RELAY WITH 2 N.O. AND 2 N.C. POWER CONTACTS.
T8775A1009
(în stoc)
COVER PLATE: T8775A1009 THERMOSTAT. HEAT ONLY APPLICATIONS. NON-PROGRAMMABLE. R & W TERMINALS. POWER STEALING. BACKLIT DISPLAY. PREMIER WHITE. ATTRACTIVE STYLING COMPLEMENTS ANY DECOR. LARGE EASY-TO-READ DISPLAY. TEMPERATURE READING IS EASILY SEEN FROM A DISTANCE. BACKLIT DISPLAY. ON-DEMAND BACKLIGHTING MAKES IT EASY TO READ DISPLAY IN A DARK ROOM OR HALLWAY. NO BATTERIES REQUIRED. TEMPERATURE SETTING IS HELD PERMANENTLY IN MEMORY IN EVENT OF A POWER FAILURE. POWERED THROUGH HEATING-COOLING SYSTEM CONTROLS. SYSTEM AND FAN SWITCHES ON T8775C MODEL. MANUAL CHANGEOVER FROM HEAT TO COOL ON T8775C MODEL. EASY INSTALLATION, SET UP AND 5-MINUTE COMPRESSOR BYPASS SAVES TIME AND INCREASES INSTALLER PRODUCTIVITY. EASILY CONFIGURABLE BY USE OF DIP SWITCHES. F OR C TEMPERATURE DISPLAY. SELECTABLE HEATING CYCLE RATES (1, 3, 6, 9 CPH) FOR A VARIETY OF APPLICATIONS.
CTS-20-250-AVG-001
(în stoc)
CURRENT SENSOR: CTS-20-250-AVG-001 SOLID CORE LOOP POWERED CURRENT SENSOR, 4-20MA OUTPUT, 0-100/0-200/0-250 AMPS
M7215A1008
(în stoc)
DAMPER MOTOR: M7215A1008 DAMPER MOTORS BY HONEYWELL PROVIDE 25 LB-IN. TORQUE WITH SPRING RETURN AND 2-10 VDC MODULATING CONTROL OF ECONOMIZER SYSTEMS, VENTILATION DAMPERS AND COMBUSTION AIR DAMPERS USED IN RESIDENTIAL OR COMMERCIAL HVAC EQUIPMENT. SYNCHRONOUS MOTOR. QUIET, HIGH EFFICIENCY DRIVE MOTOR. SPRING RETURNS MOTOR SHAFT TO NORMAL POSITION ON POWER INTERRUPTION. HIGH IMPACT, GLASS-FIBER REINFORCED PLASTIC CASE IS RUGGED, LIGHTWEIGHT AND CORROSION RESISTANT. USES Q298B LINKAGE.
V4055A1007
(în stoc)
INDUSTRIAL FLUID POWER ACTUATOR: COMBUSTION VALVE ACTUATOR
V8043E1004
(în stoc)
MOTORIZED ZONE VALVE: V8043E1004 TRADELINE. 1/2" SWEAT LOW VOLTAGE MOTORIZED ZONE VALVE. TWO-WAY ON-OFF LOW VOLTAGE VALVES BY HONEYWELL CONSIST OF AN ACTUATOR AND VALVE ASSEMBLY FOR CONTROLLING FLOW OF HOT WATER. MANUAL OPENER (ON ALL MODELS, EXCEPT STRAIGHT-THROUGH, NORMALLY OPEN VALVES) FOR VALVE OPERATION ON POWER FAILURE; VALVE RETURNS TO AUTOMATIC POSITION WHEN POWER IS RESTORED.
V8043E1020
(în stoc)
MOTORIZED ZONE VALVE: V8043E1020 1" SWEAT 24V LOW VOLTAGE TWO-WAY ON-OFF MOTORIZED ZONE VALVE BY HONEYWELL CONSIST OF AN ACTUATOR AND VALVE ASSEMBLY FOR CONTROLLING FLOW OF HOT WATER. MANUAL OPENER (ON ALL MODELS, EXCEPT STRAIGHT-THROUGH, NORMALLY OPEN VALVES) FOR VALVE OPERATION ON POWER FAILURE; VALVE RETURNS TO AUTOMATIC POSITION WHEN POWER IS RESTORED.
RP7517A1009
(în stoc)
POWER SUPPLY: RP7517A1009 ELECTRONIC - PNEUMATIC TRANSDUCER POWERED BY CONTROL SIGNAL, 30 INCH LEAD WIRE, WITH COVER, WITHOUT INTERNAL POWER SUPPLY, 2 WIRE
40003916-021
(în stoc)
POWERHEAD ASSEMBLY: 40003916-021 V8043A POWERHEAD ASSEMBLY, 2 WAY, 18" LEADS ON MANUAL OPENER END. 24/60.
40003916-023
(în stoc)
POWERHEAD ASSEMBLY: 40003916-023 V4043A POWERHEAD ASSEMBLY, 2 WAY, 18" LEADS ON MANUAL OPENER END. 240/50.
40003916-024
(în stoc)
POWERHEAD ASSEMBLY: 40003916-024 V4043A POWERHEAD ASSEMBLY, 2 WAY, 18" LEADS ON MANUAL OPENER END. 120/60.
40003916-025
(în stoc)
POWERHEAD ASSEMBLY: 40003916-025 V8044E POWERHEAD ASSEMBLY, 3 WAY, SPST END SWITCH, 18" LEADS ON MANUAL OPENER END, W/HEYCO STRAIN RELIEF. 24/60.