M7215A1008

(In Stock)

DAMPER MOTOR: M7215A1008 DAMPER MOTORS BY HONEYWELL PROVIDE 25 LB-IN. TORQUE WITH SPRING RETURN AND 2-10 VDC MODULATING CONTROL OF ECONOMIZER SYSTEMS, VENTILATION DAMPERS AND COMBUSTION AIR DAMPERS USED IN RESIDENTIAL OR COMMERCIAL HVAC EQUIPMENT. • SYNCHRONOUS MOTOR. • QUIET, HIGH EFFICIENCY DRIVE MOTOR. • SPRING RETURNS MOTOR SHAFT TO NORMAL POSITION ON POWER INTERRUPTION. • HIGH IMPACT, GLASS-FIBER REINFORCED PLASTIC CASE IS RUGGED, LIGHTWEIGHT AND CORROSION RESISTANT. • USES Q298B LINKAGE.

Info / Ask for Price

W7215B1004

(In Stock)

DIFFERENTIAL: W7215B1004 SOLID THERMOSTATE ECONOMIZER C/O CNTRL, SPDT RELAYS, 2 SENSOR INPUTS FOR DIFFERENTIAL ENTHALPY (C7400), 1 ADDITIONAL INDOOR & 1 ADDITIONAL OUTDOOR AIR SENSOR IN- PUT (2-10VDC), USE W/ HW SERIES 72 MOTORS &

Info / Ask for Price

AP5210-30

(In Stock)

DIFFERENTIAL PRESSURE: AP5210-30 AIRFLOW DIFFERENTIAL PRESSURE SWITCHES SETPOINT .30 TO 12.0 WC (.0108 TO 2.98 KPA) SWITCHING -SPST, N.C. COMP. FIT W/MANUAL RESET

Info / Ask for Price

L4064B2210

(In Stock)

FAN LIMIT CONTROLLER: L4064B2210 FAN LIMIT CONTROLLER BY HONEYWELL IS USED FOR CONTROL OF HIGH LIMIT AND FAN MOTOR IN ALL TYPES OF FORCED AIR HEATING SYSTEMS. THREE WIRING TERMINAL OPTIONS AVAILABLE FOR EASY INSTALLATION: PUSH-IN RECEPTACLES FOR STRIPPED WIRE. FEMALE RECEPTACLES FOR 1/4 IN. MALE FLAG CONNECTORS. FIELD ADD-ON SCREW TERMINALS. CONTROLS ADAPT TO MANY COMPETITIVE MOUNTING HOLES IN REPLACEMENT APPLICATIONS. AVAILABLE IN A VARIETY OF FAN AND HIGH LIMIT SETTING RANGES. L4064B,W MODELS HAVE MANUAL FAN SWITCH THAT OVERRIDES FAN CONTROL TO KEEP FAN RUNNING CONTINUOUSLY. SUPER TRADELINE MODELS INCLUDE DELUXE CASE WITH MOUNTING ADAPTERS FOR EASY INSTALLATION AND STRAIN RELIEF BUSHINGS TO PROTECT WIRING FROM FIELD ABUSE.

Info / Ask for Price

MJK100

(In Stock)

FITTING KIT: MJK100 NEW FITTING KIT - PNEUMATIC FITTINGS KIT - INCLUDES AN ASSORTMENT OF FITTINGS MOST OFTEN REQUIRED FOR REPLACEMENT OR REPAIR OF PNEUMATIC DEVICES.MJK100 NEW FITTING KIT - PNEUMATIC FITTINGS KIT - INCLUDES AN ASSORTMENT OF FITTINGS MOST OFTEN REQUIRED FOR REPLACEMENT OR REPAIR OF PNEUMATIC DEVICES.

Info / Ask for Price

RM7800G1018

(In Stock)

FLOW SWITCH: RM7800G1018 120 V/60 HZ. AIRFLOW SWITCH CHECK OPTION..

Info / Ask for Price

W8600B1005

(In Stock)

INDICATOR: W8600B1005 RF AIRWATCH INDICATOR RECEIVER

Info / Ask for Price

M436A1116

(In Stock)

INTERLOCK: M436A1116 SPRING RETURN MOTORS BY HONEYWELL ARE FOR TWO-POSITION BACK DRAFT, OUTDOOR AIR CHANGEOVER, ZONE, OR MINIMUM POSITION DAMPER CONTROL.

Info / Ask for Price

C6097A1012

(In Stock)

MANUAL RESET: HOMEYWELL C6097A1012 PRESSURE LIMIT SWITCH FOR AIR, NATURAL OR LP GAS, LOCKOUT OR PRESSURE FALL, FLANGE MOUNT MODELS CONNECT DIRECTLY TO V5097 OR V4297 VALVESNPT MOUNT, 3-21" W.C., WITH MANUAL RESET

Info / Ask for Price

L4064B2236

(In Stock)

MOUNTING ADAPTER: L4064B2236 BY HONEYWELL FOR CONTROL OF HIGH LIMIT AND FAN MOTOR IN ALL TYPES OF FORCED AIR HEATING SYSTEMS.

Info / Ask for Price

M836B1033

(In Stock)

MOUNTING BRACKET: M836B1033 DAMPER MOTOR. 15LB-IN. 75 DEG STROKE. 30 SEC OPEN. 25 SEC. CLOSE 40 SEC. 24V 60HZ. WITH CRANK ARM, UNIVERSAL MOUNTING BRACKET AND 7640JP BAG ASSEMBLY.M836B1033 SPRING RETURN MOTOR FOR TWO-POSITION BACK DRAFT, OUTDOOR AIR CHANGEOVER, ZONE, OR MINIMUM POSITION DAMPER CONTROL.

Info / Ask for Price

391959A2

(In Stock)

ORIFICE: 391959A2 ORIFICE-NAT GAS/LP AIR

Info / Ask for Price

14003757-001

(In Stock)

O-RING: 14003757-001 REPAIR PART FOR ALL RP920'S. SEAL SCREW FOR PORT 8. WITH O-RING.

Info / Ask for Price

LP916B1082

(In Stock)

PNEUMATIC THERMOSTAT: LP916B1082 PNEUMATIC REMOTE BULB THERMOSTAT DIRECT HEATING/REVERSE COOLINGTWO-PIPE, SINGLE TEMPERATURE, UNIT MOUNTED, REMOTE BULB PNEUMATIC THERMOSTAT USED TO PROVIDE PROPORTIONAL CONTROL OF PNEUMATIC VALVES AND DAMPER ACTUATORS IN HEATING AND AIR CONDITIONING SYSTEMS.

Info / Ask for Price

MN7220A2007

(In Stock)

POSITION INDICATOR: MN7220A2007 DIRECT-COUPLED DAMPER ACTUATORS BY HONEYWELL PROVIDE ADJUSTABLE MODULATING CONTROL FOR: AIR DAMPERS, VAV UNITS, AIR HANDLING UNITS, VENTILATION FLAPS, LOUVERS, AND RELIABLE CONTROL FOR AIR DAMPER APPLICATIONS WITH UP TO 4.6 M2/50 SQ FT (SEAL-LESS DAMPERS; AIR FRICTION-DEPENDENT).

Info / Ask for Price

P7810C1018

(In Stock)

PRESSURE CONTROLLER: P7810C1018 PRESSURE CONTROLLER 0-150PSI OUTPUT 4-20MA DIFFERENTIAL 5-20PSI POWER SUPPLY 120VCA AIR VAPOR SERIAL PRESSURETROL P7810

Info / Ask for Price

C6097A1004

(In Stock)

PRESSURE SWITCH: C6097A1004 PRESSURE SWITCH, AIR / GAS, 0.4" - 5" W.C AUTO RESET, 1/4" FEMALE NPT

Info / Ask for Price

C6097A1038

(In Stock)

PRESSURE SWITCH: C6097A1038 PRESSURE SWITCH. SAFETY DEVICE USED IN POSITIVE-PRESSURE OR DIFFERENTIAL-PRESSURE SYSTEMS TO SENSE GAS OR AIR PRESSURE SYSTEMS.

Info / Ask for Price

C6097A1053

(In Stock)

PRESSURE SWITCH: C6097A1053 PRESSURE SWITCH 1/4" NPT, AUTO. FOR USE WITH NATURAL GAS, LIQUID PROPANE (LP) GAS, OR AIR.

Info / Ask for Price

C6097B1028

(In Stock)

PRESSURE SWITCH: C6097B1028 PRESSURE SWITCH. 1/4" NPT, MANUAL, UNIT. USED IN POSITIVE-PRESSURE OR DIFFERENTIAL-PRESSURE SYSTEMS TO SENSE GAS OR AIR PRESSURE SYSTEMS.

Info / Ask for Price